Under Art. 3(1) CRA, a product with digital elements also includes its remote data processing solutions. The Commission examines three characteristics: processing at a distance, software designed and developed by the manufacturer or under its responsibility, and the absence of which would prevent the product from performing one of its functions. This means any function, not just the core function — commands to a device, file synchronisation, onboarding, configuration, automated update distribution or identity and access management (paras. 184–190). Whether the software runs in a public cloud, a private cloud or on the manufacturer's own servers is irrelevant (para. 187).
CRA guidance for engineering teams: getting backends, updates, components and vulnerabilities right
On 17 November 2026 the European Commission set out how the Cyber Resilience Act applies in day-to-day engineering: which cloud backend is part of the product, when an update is a substantial modification, what due diligence means for open-source components, and from when a vulnerability counts as known. This page translates guidance C/2026/6013 into decisions for architecture, release management and PSIRT.
آخر تحديث: نوفمبر 2026 · Valeri Milke, Lead Auditor لمعياري ISO 27001 وISO 42001
3characteristics decide whether a backend is part of the product as remote data processing: at a distance, needed for a function, developed by the manufacturer or under its responsibility
11examples on software updates show when a release is a substantial modification — and when it is not (Examples 40–50)
24 hearly warning after becoming aware of an actively exploited vulnerability; notification after 72 h, final report 14 days after a corrective measure is available
5years as the minimum support period — shorter only if the expected period of use is shorter
The Commission guidance on the application of the Cyber Resilience Act (C/2026/6013) runs to 257 paragraphs and 67 examples. For product management and compliance, our deep dive on the CRA guidance puts the whole document in context. This page goes one step further into the technical detail: it picks out the sections that directly affect architecture, code, build and operations, and translates them into the artefacts an engineering team has to deliver — product boundary and remote data processing, risk assessment and due diligence for components, release assessment for updates, support period and versioning strategy, vulnerability handling and reporting. Throughout, we separate what the Regulation requires, how the Commission interprets it and what VamiSec recommends. The guidance is not binding; only the Court of Justice of the EU can give a binding interpretation of the CRA.
From entry into force to application: what applies to your engineering, and when
The milestones of the Cyber Resilience Act and its guidance — with a view to what they mean for release planning, certificates and PSIRT.
10 December 2024
Entry into force of the Regulation
Regulation (EU) 2024/2847 enters into force. Its obligations apply in stages; product designs created today will be placed on the market from the end of 2027.
3 December 2025
Commission FAQ
The Commission publishes frequently asked questions on implementation — the forerunner of the guidance.
3 March – 13 April 2026
Public consultation
The draft guidance is open for consultation; in parallel, the expert group on the cybersecurity of products with digital elements provides advice.
11 June 2026
Rules for conformity assessment bodies
The provisions on the notification of conformity assessment bodies apply. For Class II and critical products, planning of third-party assessment begins.
11 September 2026
Reporting obligations under Art. 14
Actively exploited vulnerabilities and severe incidents must be reported — for all products in scope, including those already sold and no longer supported.
17 November 2026
Guidance in the Official Journal
Guidance C/2026/6013 is published in the Official Journal (C series): remote data processing, substantial modification, components, vulnerability handling and reporting are interpreted.
20 January 2027
Machinery Regulation fully applicable
Regulation (EU) 2023/1230 applies in full. Its cyber-safety requirements and certificates feed into CRA conformity via Art. 69(1) CRA.
11 December 2027
Date of application
All remaining obligations apply: essential cybersecurity requirements, vulnerability handling, conformity assessment and CE marking for every unit newly placed on the market.
11 June 2028
End of transitional validity of old certificates
EU type-examination certificates under other harmonisation legislation, for example under the delegated act to the Radio Equipment Directive, remain valid for the risks covered until this date at the latest.
Ten clarifications that affect your engineering
Click a card to read the clarification with its paragraph references — the order follows the path from architecture design through release to the PSIRT.
Only the software modules responsible for a function of the product, and their interfaces, are covered. Downstream systems with which the product does not interact directly are excluded — in the banking app use case, for example, account management and the general ledger behind the banking interface (para. 205, 8.3.1). Nor do internal systems such as HR, CRM, CI/CD pipelines or the distribution of security updates to edge locations count, or telemetry for purely statistical purposes, or penetration testing, threat hunting and red teaming (paras. 182, 192). They do, however, remain external dependencies in your risk assessment.
If you run your own software on third-party infrastructure (IaaS) or deploy your own applications on a third-party platform (PaaS), that software is developed under your responsibility and can be remote data processing. An off-the-shelf SaaS application is not — it is treated like a third-party component: assess the integration risks, mitigate them at product level, exercise due diligence (paras. 197–202). Who operates the solution is irrelevant to the classification (para. 196).
A software update is a substantial modification if it changes cybersecurity risks that the risk assessment did not take into account, or changes the intended purpose (paras. 104–107). Even a small feature can be enough: the Commission classifies a “Stay signed in” option with a persistent session as substantial, as well as a log export that stores data unencrypted (Examples 44–45). Features already provided for in the risk assessment, by contrast, do not trigger a substantial modification — even if they are only activated later (Examples 42–43).
Security updates are generally not a substantial modification: corrected input validation, hardened configurations or disabling an algorithm whose replacement was already planned (Examples 46–48). But if a security update replaces local encryption with a remote service or connects a new external key management service, the risk profile changes — and there is a substantial modification (Examples 49–50). As test questions, the Commission lists new threat vectors, new attack scenarios and changes in likelihood or impact (para. 110).
Residual risks are not measured against internal risk appetite but against whether the product achieves an appropriate level of cybersecurity for its intended purpose and reasonably foreseeable use. Internal risk tolerance, business strategy or pure cost considerations do not justify open risks; if necessary, design, functionality or intended purpose must be adjusted (paras. 157–163). The Regulation does not provide for shifting risks onto users or third parties (para. 161). User information may support secure commissioning and state residual risks, for example where use is restricted to trusted environments (Example 66).
Art. 13(2) CRA requires a risk assessment of the product, Art. 13(5) due diligence for integrated third-party components. In practice this means: first define what the product needs from a component — such as cryptography, an update mechanism or secure communication — then check on a risk basis whether the component delivers it. Suitable evidence includes technical specifications, security documentation, conformity or assurance documentation from the component manufacturer and, where appropriate, your own tests (paras. 167–173). As an integrator you are not responsible for the conformity of the component itself, but you are for your product.
You must report vulnerabilities in integrated components to the manufacturer or maintainer, for the version you integrate. This does not apply if it is established that the maintainer already knows about the vulnerability, if it only arises from your integration, or if there is no longer a maintainer. If you have developed a fix, share it — ideally machine-readable, easy to review and licence-compatible. You do not have to ensure the fix is accepted, and you do not have to adopt a fix from the maintainer (paras. 222–229).
Products must not be made available with known exploitable vulnerabilities. A vulnerability counts as known as soon as it is listed in publicly accessible vulnerability databases — such as the European vulnerability database under NIS2 —, as soon as the manufacturer learns of it from non-public sources, for example through coordinated disclosure or its own testing including AI-assisted analysis, or when reliable media report on it prominently (paras. 233–234). A short period to assess exploitability and relevance is permitted; whether a release shortly before placing on the market must be postponed is decided by the risk assessment (paras. 235–237).
The support period is at least five years, unless the expected period of use is shorter — five years is not a default value (para. 126). For software, you may fix vulnerabilities only in the latest version if users can update free of charge and without additional costs. Routine effort such as testing, configuration or dependency upgrades does not count as additional costs; mandatory new hardware or a fundamental change of environment does (paras. 129–130). Reporting obligations continue, even after the end of support (para. 210).
Substantial modification? The guidance's update examples
Six typical release situations from Sections 4.3 and 8.2 of the guidance — with the Commission's classification and what your release process should take from it.
Substantial modificationExamples 40–41
- A dashboard that previously only displayed machine data gains the ability to control machines via an update.
- After the update, a consumer app makes automated decisions it did not make before.
- New functions that change the intended purpose are generally a substantial modification (para. 105).
- For the release process: treat changes of purpose as a separate gate, and redo the risk assessment and conformity assessment for the modified parts.
Guidance 4.3Paras. 104–105Art. 3(30) CRA
No substantial modificationExamples 42–43
- A group chat already taken into account in the risk assessment is delivered later.
- Control loops were assessed and shipped, but remain deactivated until activation.
- Features whose risks have already been assessed do not trigger a substantial modification (para. 106).
- For the release process: include planned features in the risk assessment early — it saves a reassessment later.
Guidance 4.3Para. 106
Substantial modificationExamples 44–45
- A “Stay signed in” option introduces persistent sessions.
- A new log export stores data unencrypted.
- The scope of the change is irrelevant; what matters is whether the risk profile changes (para. 107).
- For the release process: check every change to authentication, sessions, data storage and interfaces against the risk assessment, even for small tickets.
Guidance 4.3Para. 107Para. 110
Generally no substantial modificationExamples 46–48
- Faulty input validation is corrected.
- Configurations are hardened.
- An algorithm is disabled whose replacement was already provided for in the risk assessment.
- Security updates are in principle not a substantial modification (para. 108) — the risk assessment and technical documentation must nevertheless be kept up to date (para. 113).
Guidance 4.3Para. 108Para. 113
Substantial modificationExamples 49–50
- Local encryption is replaced by a remote service.
- A new external key management service is connected.
- Even a security update can be substantial if it creates new threat vectors or attack scenarios (paras. 109–110).
- For the release process: assess architectural decisions in security fixes separately — especially when protective functions move to cloud services.
Guidance 4.3Paras. 109–112
No substantial modificationPara. 208
- If a third-party provider fundamentally changes its remote solution, this is not a substantial modification of your product — the solution is not under your responsibility.
- The Commission encourages manufacturers to arrange to be informed of changes by cloud providers.
- On that basis, the risk assessment may need to be revised: does the provider still offer sufficient guarantees, are the product-level controls adequate?
- For the release process: anchor change notifications and security commitments in SLAs and define them as triggers for a reassessment.
Guidance 8.2Para. 208
Interactive
Is your backend part of the product? The remote data processing check
Up to five questions along the criteria in Section 8 of the guidance. Check each remote component individually — app backend, authentication service, update server, third-party service. The result does not replace a case-by-case assessment.
Your path
- 1?
1: Is data for your product processed outside the device or the user's environment — in the cloud, at the edge or on servers in your data centre?
1
Is data for your product processed outside the device or the user's environment — in the cloud, at the edge or on servers in your data centre?
“At a distance” is not exhaustively defined. Processing outside the user's environment is typical; edge processing close to the device, on-premises and private cloud also count. Whether transmission is wired or wireless makes no difference (paras. 185–187).
This component is remote data processing — it is part of the product
All criteria are met: the processing takes place at a distance, supports a function of your product, was developed under your responsibility and interacts directly with the product. It is therefore part of the product with digital elements — from the risk assessment through the essential cybersecurity requirements to the reporting obligations.
- Identify and describe it in the technical documentation; if the same solution serves several products, list it in each documentation — the material may be reused (para. 204).
- Apply the essential cybersecurity requirements on a risk basis to this software and its interfaces, not to your entire IT infrastructure (paras. 181–182).
- If it runs on third-party IaaS or PaaS: document the dependency and check the provider's security measures, for example via evidence of NIS2 obligations (8.3.2, 8.3.4).
- Vulnerabilities and severe incidents in this software fall under the reporting obligations of Art. 14 (para. 178).
Guidance 8.1–8.2Paras. 178–208Art. 3(2) CRA
Downstream system — not remote data processing, but a risk
Systems with which your product does not interact directly are not part of remote data processing, even if their availability is needed for a function. They do, however, remain external dependencies whose risks you must capture in the risk assessment and mitigate at product level.
- Include the risks in the assessment under Art. 13(2) — for example the compromise of a general ledger system in the banking example (8.3.1).
- Provide product measures: cryptographic authentication of remote commands, integrity checks of configuration changes, security-relevant logging or alerts on anomalous behaviour (para. 169).
- Plan for failures: if an external service fails, the product must not fall into an insecure state (para. 169).
- Our recommendation: make the boundary between remote data processing and downstream systems visible in the architecture diagram — it is one of the first questions in any assessment.
Guidance 7.3Paras. 168–169Paras. 205–206
Third-party remote solution — treat it like a component
The processing is needed for a function but was not developed by you or under your responsibility, for example a SaaS application, a chat service or a storage service. It is not remote data processing of your product. The Commission requires it to be treated like a third-party component.
- Assess integration risks and mitigate them at product level — for example secure authentication, encryption and integrity protection of communication (8.3.3) or isolation and content checks of an embedded chat (8.3.1).
- Exercise due diligence, proportionate to the risk (paras. 201–202).
- Use evidence: compliance with Implementing Regulation (EU) 2024/2690 or DORA, certificates under the Cybersecurity Act, ISO/IEC 27017:2015 or ISO/IEC 27001:2022 (para. 207).
- Govern security commitments, vulnerability handling and change notifications in SLAs; if the provider changes its service, this is not a substantial modification of your product but may trigger a reassessment (para. 208).
Guidance 8.1.3–8.2Paras. 200–208Art. 13(5) CRA
Without a link to a function, there is no remote data processing
If the absence of the processing does not prevent any function of your product, it is not remote data processing. This applies, for example, to telemetry for purely statistical purposes or for future product development, and to websites that only provide information — even if the product links to them.
- Check whether the component nevertheless poses risks to the product, and mitigate them at product level (para. 193).
- Caution with websites: an authentication portal that issues credentials or tokens the product needs to operate can be remote data processing (para. 194).
- Also not remote data processing: internal systems such as CRM or CI/CD, the distribution of updates to edge locations, and penetration testing and red teaming (para. 182).
Guidance 8.1.2Paras. 189–194
Networks are neither remote data processing nor a component
Mobile networks, routers, Wi-Fi or Ethernet enable communication but are not data processing whose absence prevents a function. According to the mobile network use case, the network is also not to be treated like a third-party component, because no software is integrated into your product.
- No due diligence towards the network operator required (8.3.5).
- The ability to connect correctly to a network, on the other hand, is a function of your product.
- Network-side threats still belong in the risk assessment — addressed, for example, through secure communication at product level.
Guidance 8.3.5
Local processing is part of the product anyway
Whatever runs on the device or in the user's environment is part of the product itself — firmware, operating system, app or locally installed software. The question of remote data processing only arises when data is processed elsewhere.
- Hardware and software needed for the intended functions form one product — even if drivers or a companion app are downloaded separately (Examples 8–9).
- Software that runs on the user's side is a product — including browser extensions and locally installed applications built on web technology (para. 20, Example 4).
- Run the check again for every online service your product uses.
Guidance 2.2–2.4Examples 3–9
- Is data for your product processed outside the device or the user's environment — in the cloud, at the edge or on servers in your data centre?
- Is the component merely a communication channel — mobile network, router, Wi-Fi or cable?
- Would your product be unable to perform one of its functions without this processing?
- Did you design and develop the software for this processing yourself — or have it custom-developed for you?
- Does your product interact directly with this software module?
Long read
The CRA guidance in engineering: ten chapters from the product boundary to the PSIRT
Ten chapters translate Sections 2, 4, 5, 7, 8 and 9 of the guidance into architecture, release and operations decisions. Paragraph references (para.) and examples refer to C/2026/6013.
What the guidance means for engineering teams — and how to read it
The guidance is addressed to economic operators as well as to market surveillance authorities and notified bodies. Anyone developing products should read it as a preview of the questions an assessment will ask.
The notice “Commission guidance on the application of Regulation (EU) 2024/2847 (Cyber Resilience Act)” was published in the Official Journal of the EU (C series) on 17 November 2026. Its legal basis is Art. 26 CRA: the Commission is to support economic operators, in particular micro, small and medium-sized enterprises, in applying the Regulation and to explain at least the scope, including remote data processing and open source, the support period, substantial modification and the interplay with other EU law.
257paragraphs in nine sections
67examples, 11 of them on software updates
5use cases on remote data processing
9sections — central for engineering are 2, 4, 5, 7, 8 and 9
The guidance expressly does not cover the Regulation in full. For engineering teams, five topics are particularly relevant, and we explore them in depth on this page. The complete overview, including open source, spare parts and product classes, is provided by our deep dive on the CRA guidance.
| Section of the guidance | Engineering question | Team artefact |
|---|---|---|
| 2.2–2.4, 7.4 | What is part of the product, what is a variant? | Product boundary, variant matrix |
| 8 | Which backends are remote data processing? | Architecture diagram with system boundaries |
| 7.1–7.3 | How are risks assessed and components checked? | Risk assessment, threat model, component evidence |
| 4.3–4.4, 5.1 | Is this release a substantial modification? | Release gate with risk delta |
| 5 | How long is support provided, which versions are patched? | Support policy, end-of-life communication |
| 9.1–9.2 | How are vulnerabilities handled, reported and shared upstream? | PSIRT process, CVD policy, SBOM |
Product boundaries: software, web applications, companion apps and product families
Before a risk assessment begins, it must be clear what the product is. The guidance draws the line by function, not by delivery channel.
Software as a product
Software is a product with digital elements if it is provided to the user and runs on their system. This includes downloaded mobile apps, desktop applications built on web technology and browser extensions (para. 20, Examples 3–4). Web applications accessed exclusively in the browser and pure information websites are not a product in themselves (para. 21, Examples 5–6) — but they can be remote data processing of a product.
Hardware and software as one product
What matters is whether software is needed for the product to perform its intended functions — not how it is delivered. A network printer with separately downloaded drivers is just as much one product as a fitness wearable with a companion app (para. 25, Examples 8–9). For your architecture this means: companion app, drivers and firmware belong in the same risk assessment.
Source code and unfinished software
- Sharing code in public repositories is generally not placing on the market; this also applies to unfinished code and to demo and tutorial code (para. 23).
- Anyone who supplies source code to customers as a product places it on the market. The supplier is not responsible for subsequent modifications by the customer (para. 24, Example 7).
- Alpha and beta versions and release candidates may be made available without full conformity, provided this is only for the time needed for testing and gathering feedback (Art. 4(3) CRA, footnote 8).
- Versions that are not a substantial modification do not move the point at which standalone software is placed on the market (para. 15, Examples 1–2).
Variants and product families
If variants, models or configurations share the same architecture, the same security-relevant design and the same purpose and are exposed to the same risks, one risk assessment, one technical documentation, one conformity assessment procedure and one EU declaration of conformity that clearly identifies the variants are sufficient (paras. 174–175). Colour, form factor or storage size are not security-relevant; different communication interfaces, software stacks, update mechanisms or remote access are (para. 176).
| Difference between variants | Security-relevant? | Consequence |
|---|---|---|
| Colour, housing, form factor | No | Joint assessment and documentation |
| Storage size | No | Joint assessment and documentation |
| Different communication interface | Yes | Reflect in the risk assessment and, where applicable, the conformity assessment |
| Different software stack | Yes | Reflect in the risk assessment and, where applicable, the conformity assessment |
| Different update mechanism | Yes | Reflect in the risk assessment and, where applicable, the conformity assessment |
| Additional remote access | Yes | Reflect in the risk assessment and, where applicable, the conformity assessment |
Remote data processing: which backend is part of the product
Section 8 is the most important part of the guidance for cloud-connected products. It answers which server software you must secure, document and report on as part of your product.
Art. 3(2) CRA defines remote data processing as data processing at a distance for which the software is designed and developed by the manufacturer, or under its responsibility, and the absence of which would prevent the product from performing one of its functions. The software elements are covered; the hardware on which they run is not part of the product (para. 180). The aim is to secure products as a whole — regardless of whether data is processed locally or by the manufacturer. The CRA therefore does not require measures for the manufacturer's entire network and information systems (para. 181).
- 1At a distance?
Processing outside the user's environment, including at the edge, on-premises or in a private cloud. Necessary, but not sufficient (paras. 185–187).
- 2Needed for a function?
Any function counts, not just the core function: sending commands, synchronising, onboarding, configuration, update distribution, identity and access management (paras. 189–190).
- 3Developed by the manufacturer?
In-house development or custom-developed under its responsibility; the operator is irrelevant (paras. 195–196).
- 4Direct interaction?
Only modules responsible for the function, and their interfaces; downstream systems are not covered (para. 205).
Cloud service models
| Model | What the manufacturer controls | Classification under the guidance |
|---|---|---|
| IaaS (third party) | Operating systems and applications on third-party resources | Own software can be remote data processing; treat hypervisor and hardware like a component (paras. 198, 201) |
| PaaS (third party) | Own application, possibly configuration of the runtime environment | Own application can be remote data processing; treat platform and operating system like a component (paras. 199, 201) |
| SaaS (third party) | Only user-specific settings | Not remote data processing; treat as a component subject to due diligence (paras. 200–201) |
| Own servers, private cloud | Everything | Can be remote data processing, like public cloud (para. 187) |
What is expressly excluded
- Internal systems for HR, payroll and customer relationship management (para. 182).
- CI/CD pipelines and the distribution of security updates to edge locations (para. 182).
- Penetration testing, threat hunting and red teaming — although testing is an essential requirement, this does not make it part of the product (para. 182).
- Telemetry for purely statistical purposes or for future product development (para. 192).
- Websites that only contain information or instructions, even if the product links to them (para. 194).
The Commission's five use cases
| Use case | Component | Classification |
|---|---|---|
| Banking app | In-house developed banking interface | Remote data processing |
| Banking app | Account management and general ledger behind it | Not remote data processing, but an external dependency |
| Banking app | Support chat as SaaS | Not remote data processing; treat like a component, isolate the chat, check content |
| Smart thermostat | Own software on third-party IaaS | Remote data processing; document and check the IaaS |
| E-reader | Third-party SaaS storage service | Not remote data processing; treat like a component |
| Industrial robot | Own image processing service on third-party IaaS | Remote data processing; e.g. request NIS2 evidence from the provider |
| Smartphone | Mobile network | Neither remote data processing nor a component |
Guidance 8.3.1–8.3.5. The use cases are fictitious and archetypal; they do not replace a case-by-case assessment.
Documentation and evidence
- Identify and describe remote data processing and the third-party solutions used in the technical documentation (para. 204).
- If the same solution serves several products, it is listed in each product's documentation; the material may be reused (para. 204).
- The risk assessment covers risks of the remote data processing, of dependence on third-party solutions and of the environment, such as the underlying hardware (para. 206).
- As evidence for third-party providers, the Commission lists compliance with Implementing Regulation (EU) 2024/2690 or DORA, statements or certificates under the Cybersecurity Act, and ISO/IEC 27017:2015 or ISO/IEC 27001:2022 (para. 207).
- Security guarantees belong in the SLAs, including the commitment that the provider handles vulnerabilities appropriately (para. 208).
Risk assessment: appropriate security instead of risk appetite
Sections 7.1 and 7.2 specify what residual risks are measured against. For teams that do threat modelling, this is the most important clarification on risk acceptance.
The risk assessment under Art. 13(2) CRA identifies relevant risks, assesses their impact and requires measures in line with the essential cybersecurity requirements in Annex I (para. 156). Unlike in organisational risk management, residual risks are not measured against acceptance criteria derived from internal objectives, but against whether the product achieves an appropriate level of cybersecurity for its intended purpose and reasonably foreseeable use (para. 157).
No cost argument
Internal risk tolerance, business strategy or pure cost considerations are not decisive (para. 158). If risks cannot be adequately addressed, changes to design, functionality or intended purpose may become necessary (para. 163).
No shifting of risk
The CRA does not provide for transferring risks or responsibility to users or third parties to compensate for design shortcomings (para. 161).
Product-level measures
Reduce the attack surface, implement technical safeguards, limit functionality or narrow the purpose; steer foreseeable use through risk communication, user guidance and interface design (para. 160).
User information with a sense of proportion
Instructions may support secure operation and state residual risks, for example where the purpose is restricted to trusted environments (para. 162).
Two practical examples
- Example 66: For functional reasons, an industrial sensor has no protection against physical attacks. The manufacturer restricts the purpose to trusted environments without unauthorised physical access and informs users clearly about this.
- Example 67: A business app for managed devices does not encrypt locally stored sensitive data with an in-house implementation, but uses the operating system's mature, maintained encryption and key management.
The catch-all requirement in Annex I, Part I, point 1
Products must be designed, developed and produced in such a way that they ensure an appropriate level of cybersecurity based on the risks. This requirement addresses all risks not already covered by the other essential cybersecurity requirements. If all risks are addressed through the other requirements, it is deemed fulfilled; in most cases, meeting the other requirements leads to meeting this one (paras. 164–166).
External risks
You do not have to control risks from networks, the environment or back-end systems outside the product, but you do have to identify them and mitigate them through product design (para. 168). The Commission mentions, for example, cryptographic authentication of remote commands, integrity checks of configuration changes and security-relevant logging or alerts on anomalous behaviour. If an external service fails, for instance due to a power outage or infrastructure fault, the product must not fall into an insecure state (para. 169).
Components and open source: due diligence you can evidence
Almost every product consists mostly of third-party code. The guidance describes what integrators must check — and what they are not responsible for.
The risk assessment under Art. 13(2) and due diligence under Art. 13(5) are separate, complementary obligations (para. 167). Due diligence concerns elements that are part of the product, in particular integrated third-party software or hardware components. They must not undermine the product's conformity (para. 170).
- 1Define the need
Derive from the risk assessment what the product needs from the component — such as cryptographic functions, an update mechanism or secure communication (para. 171).
- 2Obtain evidence
Technical specifications, security documentation, conformity or assurance documentation from the component manufacturer (para. 171).
- 3Verify on a risk basis
Where appropriate, your own tests of whether the component delivers the functions (para. 171).
- 4Treat as external
Take third-party components into account in the risk assessment, but for conformity purposes treat them as supplied components whose properties have been checked through due diligence (para. 172).
Open-source components
- Anyone integrating open-source components is not responsible for their conformity, but must make their own product conformant, exercise due diligence, and report vulnerabilities and share fixes upstream (paras. 85–88).
- Merely contributing code does not make you a manufacturer; responsibility lies with whoever publishes and controls releases, roadmap and governance (paras. 47–49).
- Even third-party-funded open source does not release integrating companies from their due diligence obligation (paras. 63–65).
Developed in-house or integrated
What you develop yourself must implement the essential cybersecurity requirements directly. What you integrate, you must check through due diligence so that the product as a whole is conformant. The goal is the same in both cases: an appropriate level of cybersecurity of the product as placed on the market (para. 173).
Substantial modification: a release gate for software updates
With eleven examples, Section 4.3 is the most practical part of the guidance. It answers the question every release board should ask: does this update change the risk profile?
Under Art. 3(30) CRA, a substantial modification is a change after placing on the market that affects compliance with the essential cybersecurity requirements in Annex I, Part I, or changes the assessed intended purpose (para. 90). For software updates, the Commission asks whether cybersecurity risks change that the risk assessment did not take into account (para. 104).
| Test question | Example from the guidance | Result |
|---|---|---|
| Does the intended purpose change? | Dashboard gains machine control (Ex. 40) | Substantial |
| Was the feature provided for in the risk assessment? | Group chat delivered later (Ex. 42) | Not substantial |
| Does a new risk arise, even from a small change? | “Stay signed in” (Ex. 44) | Substantial |
| Is it a security update without new risk? | Input validation corrected (Ex. 46) | Not substantial |
| Does the security update move protective functions? | Local encryption replaced by a remote service (Ex. 49) | Substantial |
Four factors for the assessment
- Does the change introduce new threat vectors?
- Does it enable new attack scenarios?
- Does it change the likelihood of known risks?
- Does it change the impact of known risks?
If none of these factors changes, there is probably no substantial modification; otherwise a reassessment is required (paras. 110–112). Regardless of this, vulnerability handling, the risk assessment and the technical documentation must be kept up to date (para. 113, Art. 13(7), Art. 31(2) CRA).
What a substantial modification triggers
- The modified product is deemed newly placed on the market (para. 116).
- The original manufacturer remains the manufacturer and may reuse documentation and tests for unaffected parts; the conformity assessment focuses on the modified parts (paras. 122–123).
- Third parties who carry out a substantial modification and make the product available become the manufacturer of the modified product, with obligations in principle only for the affected part (paras. 117–121).
- Integrating components into a new product is not a substantial modification; the integrator is the manufacturer of the new product (para. 120, Example 51).
- Every substantially modified software version needs its own support period (para. 128). It is reassessed, but not automatically extended (para. 133).
Support period and versioning strategy
How long you deliver security updates and which versions you patch is an architecture and product decision with regulatory effect.
The support period reflects the expected period of use, measured against reasonable user expectations, the nature and purpose of the product and relevant EU law on product lifetime (para. 125). It is at least five years, unless the expected period of use is shorter; longer lifetimes justify longer periods, and five years is not a default value (para. 126).
- The end date, at least month and year, must be stated at the time of purchase; where technically feasible, users are notified when it expires (Art. 13(19) CRA, para. 127).
- As further criteria, the Commission lists the support periods of comparable products, the availability of the operating environment and the support periods of integrated third-party components providing core functions (footnote 17).
- Public archives with older versions are permitted if users are clearly informed about the risks of unsupported software (Art. 13(11), footnote 7).
Patch only the latest version?
Under Art. 13(10) CRA, vulnerability remediation may be limited to the latest version if users can update earlier versions free of charge and without additional costs (para. 129). You may continue to maintain older versions, including for a fee (footnote 19). Coordinated disclosure, information sharing and reporting obligations remain unaffected (para. 131).
| Effort on the user's side | Additional costs? |
|---|---|
| Testing, configuration, dependency upgrades | No — normal operational effort |
| Mandatory new hardware | Yes |
| Replacement of infrastructure | Yes |
| Fundamental change of operating environment | Yes |
Para. 130. Example 52 (smartphone operating system) and Example 53 (enterprise software with updates every few months) illustrate the rule.
Support period after a substantial modification
If the factors determining the expected period of use stay the same, the period is based on the remaining original period of use — for example for a robot vacuum cleaner or the re-architecture of a cloud backend (para. 134, Examples 54–55). If they change, for example through a PLC platform change that extends its lifetime, it must be recalculated (para. 135, Example 56).
Vulnerability handling: known, upstream, tested
Section 9.2 clarifies three questions that come up in every PSIRT: when is a vulnerability known? To whom must I report it? And what does regular testing mean?
Known exploitable vulnerabilities
An exploitable vulnerability is one that an attacker can effectively use under practical operational conditions; some vulnerabilities can only be exploited in a laboratory or simulation (Art. 3(41) CRA, para. 231). It is known if it is listed in publicly accessible vulnerability databases, such as the European vulnerability database under Art. 12(2) NIS2 (para. 233), if the manufacturer learns of it from non-public sources — coordinated disclosure, its own testing and analysis, including with AI-assisted services — or if reliable media report on it prominently (para. 234).
- A reported or discovered vulnerability is not automatically exploitable or relevant to your product; a short period for assessment is permitted, with the emphasis on prompt action (para. 235).
- The obligation applies at the time of placing on the market. If a vulnerability becomes known shortly before, the risk assessment decides whether the product can be placed on the market safely or whether the fix is needed first (paras. 236–237).
- The weighing includes severity, exploitability and impact, but also the risks of a delay — for example if the new release closes other exploitable vulnerabilities or is needed for critical systems (para. 237).
Reporting and sharing upstream
| Situation | Obligation under Art. 13(6) |
|---|---|
| Vulnerability in the integrated version of a component | Report upstream, via the maintainer's established channels and CVD processes |
| Maintainer demonstrably knows about the vulnerability | No report needed; avoid duplicates, for example by checking databases, advisories and issue trackers |
| Vulnerability only arises from your integration | No report needed; pointing out anomalous behaviour is recommended |
| No maintainer any more, or you no longer obtain versions from the maintainer | No report needed; informing users via community channels or public vulnerability entries is recommended |
| You have developed a fix | Share with the maintainer: machine-readable, reviewable, licence-compatible, following the maintainer's guidelines |
| You mitigate differently, for example through configuration | Sharing not required, but recommended |
Paras. 222–229. You do not have to ensure the fix is accepted, and you do not have to adopt a fix from the maintainer (para. 228).
Effective and regular testing
Annex I, Part II, point 3 requires effective and regular tests and reviews during the support period. Regular does not mean repeating an unchanged test campaign at fixed intervals, but regularly checking whether new threats or vulnerabilities require the tests to be adapted, and then testing accordingly — including regression tests after changes (paras. 238–239). If the review produces no new input, no additional tests need to be developed (para. 240).
Reporting obligations: when the clock starts and what must be reported
Since 11 September 2026, actively exploited vulnerabilities and severe incidents must be reported. Section 9.1 clarifies when the deadlines start and the limits for third-party components.
Manufacturers notify simultaneously the CSIRT designated as coordinator and ENISA of any actively exploited vulnerability in their product and any severe incident having an impact on its security (Art. 14(1) and (3) CRA, para. 209). Since 11 September 2026 the obligation applies to all products in scope, including those placed on the market before 11 December 2027, and, unlike vulnerability handling, also after the end of the support period (para. 210).
24 hearly warning with limited information
72 hnotification with further information
14 daysfinal report after a corrective measure is available, for vulnerabilities
1 monthfinal report after the 72 h notification, for incidents
When the manufacturer becomes aware
A suspicious event — discovered in-house or reported by customers, researchers, authorities or the media — must be assessed immediately. The manufacturer becomes aware as soon as, after this initial assessment, it has a reasonable degree of certainty that a vulnerability in its product is being actively exploited or that a severe incident has affected the security of its product (para. 213). The Commission aligns this understanding with Implementing Regulation (EU) 2024/2690 under NIS2 and with Guidelines 9/2022 on personal data breach notification under the GDPR (para. 212).
Limits of the reporting obligation
- No retroactive reporting: if you already knew of the active exploitation before 11 September 2026, there is nothing to report. If you only knew of the vulnerability and learn of its exploitation afterwards, the obligation applies (para. 217).
- Third-party components: if a vulnerability in a component in your product is actively exploited, you report. If it is not exploitable in your product — for example because the vulnerable code is not reachable — or has not been exploited there, it is not reportable for you; voluntary reporting under Art. 15 remains possible (para. 218).
- Open-source software stewards report actively exploited vulnerabilities under Art. 24(3) to the extent they are involved in development — triggered by becoming aware of the exploitation, not by the mere existence of the vulnerability in the code (para. 216).
Informing users
Under Art. 14(8), affected users and, where appropriate, all users must be informed — on a risk basis and proportionately. This does not mean making details public: particularly for products in sensitive or essential environments, the information can be limited to affected customers (paras. 219–220). Once the vulnerability has been fixed, broader disclosure may make sense; under Annex I, Part II, point 4, fixed vulnerabilities must be disclosed once a security update has been made available (para. 221).
Legacy designs, existing certificates and a roadmap to 11 December 2027
Many products sold from the end of 2027 are already designed today. The guidance shows what this means for redesign, certificates and vehicle components.
Products designed before the CRA
Units placed on the market after 11 December 2027 do not necessarily have to be redesigned. The risk assessment decides which requirements of Annex I, Part I are applicable; existing measures may be relied upon (paras. 33–34). The EU declaration of conformity and CE marking remain mandatory; historical design and test documentation does not have to be recreated (paras. 35, 38–39, Example 12).
Existing certificates under Art. 69(1)
EU type-examination certificates and approvals relating to cybersecurity requirements under other harmonisation legislation remain valid until 11 June 2028, unless they expire earlier — but only for the risks they cover (paras. 247–248). For the Radio Equipment Directive, the Commission mentions network protection, protection of personal data and fraud prevention; for the Machinery Regulation, protection against corruption and the safety and reliability of control systems (paras. 251–256). This does not replace a comprehensive CRA risk assessment; gaps such as vulnerability handling, data minimisation or attack surface reduction still have to be closed (paras. 249–250, 253).
Vehicle components
Components designed and built exclusively for vehicles under Regulations (EU) 2019/2144 or (EU) No 168/2013 do not fall under the CRA (para. 244). Generic components that also fit other products, or those sold to the general public through open channels such as online shops, are subject to the CRA — regardless of statements on their use (paras. 245–246).
Roadmap for engineering teams
- 1Draw the product boundary
Define variants, companion apps, drivers and remote data processing for each product and document them in the architecture diagram.
- 2Set up the risk assessment
Threat model per product family with acceptance criteria based on appropriate security, including external dependencies and failure behaviour.
- 3Evidence components
Link the SBOM with due diligence evidence for security-critical components and cloud services; tighten SLAs.
- 4Introduce a release gate
Four substantial modification factors in change templates; result in the technical documentation.
- 5Define the support policy
Plan the support period, versioning strategy and end-of-life communication against dependencies.
- 6Make the PSIRT operational
Point of becoming aware, 24 h, 72 h and final reports, upstream reporting, fix sharing and user information as a rehearsed process.
- 7Review tests regularly
Document the review cycle for new threats and vulnerabilities, adapted tests and regression tests.
This page reflects the Commission's interpretation and our assessment; it is not legal advice. The authoritative text is the wording of the Regulation and the guidance as published in the Official Journal.
Complete overview
All of the Commission's clarifications: the deep dive on the CRA guidance
This page focuses on architecture, release and PSIRT. Our deep dive in the GRC topic area offers the complete overview of the guidance — scope and placing on the market, open source and open-source software stewards, spare parts, core functionality and product classes, presumption of conformity — with a scope navigator, a case navigator covering all 67 examples, a gap analysis and a CISO white paper.
C/2026/6013Commission guidance, OJ C of 17 November 2026
Regulation (EU) 2024/2847binding obligations, classes and deadlines
Gap analysis45 questions in the GRC deep dive
- Scope navigator: does the CRA affect your product, your service or your open-source project?
- Case navigator with all 67 examples and five use cases
- Long read in 14 chapters, glossary with the official CRA terminology
The authoritative text is the wording published in the Official Journal.
VamiAppSec
هكذا تطبّقون ذلك في خط CI/CD لديكم
يُنشئ VamiAppSec قائمة SBOM لكل إصدار ضمن CI/CD لديكم، ويراقب المكونات المُسلَّمة بحثًا عن ثغرات مستغَلة بشكل نشط، ويُعدّ بلاغات المادة 14 – بينما توفر SAST وSCA وDAST المدعوم بالذكاء الاصطناعي الأدلة اللازمة للملحق الأول.
Glossary
Glossary: CRA terms for engineering teams
The key terms on this page in the English terminology of the guidance, with the corresponding term from the official German version.
18 of 18 terms
- Product with digital elementsProdukt mit digitalen Elementen
- A software or hardware product and its remote data processing solutions, including components placed on the market separately (Art. 3(1) CRA).
- Remote data processing (RDPS)Datenfernverarbeitung
- Data processing at a distance for which the software is designed and developed by the manufacturer, or under its responsibility, and the absence of which would prevent the product from performing one of its functions (Art. 3(2) CRA).
- External dependencyExterne Abhängigkeit
- A system outside the product, such as a downstream back end, whose risks must be captured in the risk assessment and mitigated at product level without it becoming part of the product.
- Cybersecurity risk assessmentBewertung der Cybersicherheitsrisiken
- The obligation under Art. 13(2) CRA to identify relevant risks of the product, assess their impact and derive measures in accordance with Annex I.
- Residual riskRestrisiko
- Risk remaining after measures have been implemented; it must be appropriately addressed in light of the intended purpose and reasonably foreseeable use and may not be accepted at the manufacturer's discretion.
- Due diligenceSorgfaltspflicht
- The obligation under Art. 13(5) CRA to ensure that integrated third-party components do not undermine the product's conformity.
- Substantial modificationWesentliche Änderung
- A change after placing on the market that affects compliance with the essential cybersecurity requirements or changes the assessed intended purpose (Art. 3(30) CRA).
- Security updateSicherheitsaktualisierung
- An update to remediate vulnerabilities; generally not a substantial modification, unless it creates new, unassessed risks.
- Support periodUnterstützungszeitraum
- The period during which vulnerabilities are handled; at least five years, unless the expected period of use is shorter (Art. 13(8) CRA).
- Family of products with digital elementsProduktfamilie
- Variants with the same architecture, the same security-relevant design, the same intended purpose and the same risks; they may be assessed and documented jointly.
- Exploitable vulnerabilityAusnutzbare Schwachstelle
- A vulnerability that an attacker can effectively use under practical operational conditions (Art. 3(41) CRA).
- Known exploitable vulnerabilityBekannte ausnutzbare Schwachstelle
- An exploitable vulnerability that is listed in public databases, is known to the manufacturer from non-public sources, or has been reported prominently in reliable media.
- Actively exploited vulnerabilityAktiv ausgenutzte Schwachstelle
- A vulnerability for which there is reliable evidence of exploitation by an attacker; it triggers the reporting obligation under Art. 14 CRA.
- Reporting upstreamVorgelagerte Meldung
- Reporting a vulnerability in an integrated component to its manufacturer or maintainer (Art. 13(6) CRA).
- Sharing upstreamSicherheitskorrektur teilen
- Passing on a self-developed fix for a component to its manufacturer or maintainer, ideally machine-readable and licence-compatible.
- Becoming awareKenntnis
- The point from which the reporting deadlines run: when, after an initial assessment, the manufacturer has a reasonable degree of certainty of active exploitation or a severe incident.
- Shared responsibility modelModell der geteilten Verantwortung
- The division of security tasks between cloud provider and customer; its security functions can support the manufacturer's product-level measures.
- MaintainerMaintainer
- A person or entity that publishes open-source software and controls releases, roadmap and governance; mere contributors are not responsible.
FAQ
Frequently asked questions from engineering and product security
Short answers to typical questions from architecture, release management and PSIRT — with references to the paragraphs of the guidance.
A web application accessed only in the browser is not a product in itself. A backend does, however, become part of a product if, as remote data processing, it supports a function of an app, a device or locally installed software and was developed under your responsibility (para. 21, Section 8).
The Commission expressly excludes the CI/CD pipeline and the distribution of security updates to edge locations from remote data processing (para. 182). A service that distributes updates to the product automatically, on the other hand, can support a function of the product (para. 190). Check the specific role in the backend check.
No. What matters is whether the update creates risks that the risk assessment did not take into account, or changes the purpose. Anticipated features are unproblematic; small changes that introduce a new risk, however, are not (paras. 104–107, Examples 40–45).
Generally not — security updates are in principle not a substantial modification (para. 108). It is different if the update moves, for example, encryption or key management into new remote services (Examples 49–50). The risk assessment and documentation must be kept up to date in any case (para. 113).
Yes, if users can update to the latest version free of charge and without additional costs. Testing, configuration and dependency upgrades on the user's side do not count as additional costs; mandatory new hardware does (Art. 13(10) CRA, paras. 129–130).
No. Under Art. 14, actively exploited vulnerabilities in your product must be reported. If the vulnerability is not exploitable in your product, for example because the code is not reachable, or has not been exploited there, the reporting obligation does not apply to you. Vulnerability handling and reporting upstream remain (para. 218).
If you have developed a software change that fixes a vulnerability in an integrated component, you must share it with the maintainer — ideally machine-readable and licence-compatible. You do not have to ensure that the fix is accepted (paras. 226–228).
As soon as it is listed in publicly accessible vulnerability databases, as soon as you learn of it from non-public sources such as coordinated disclosure or your own testing, including AI-assisted testing, or as soon as reliable media report on it prominently. A short period for assessment is permitted (paras. 233–235).
From becoming aware: when, after an immediate initial assessment, you have a reasonable degree of certainty that a vulnerability in your product is being actively exploited or that a severe incident has affected the security of your product (para. 213).
They are useful evidence for due diligence towards third-party providers — the Commission expressly mentions ISO/IEC 27001:2022 and ISO/IEC 27017:2015 (para. 207). They do not replace a product-specific risk assessment and the implementation of the essential cybersecurity requirements in the product.
No, if they have the same architecture, the same security-relevant design and the same purpose and are exposed to the same risks. Differences in interfaces, software stack, update mechanism or remote access must, however, be reflected (paras. 174–177).
No. It reflects the Commission's interpretation; only the Court of Justice of the EU can give a binding interpretation of the CRA. However, it is also addressed to market surveillance authorities and notified bodies and will shape their expectations (para. 8).
المعايير والمصادر
يستند محتوى هذه الصفحة إلى الأدلة والدراسات التالية المتاحة للعموم.
European Commission · 2026
Commission guidance on the application of Regulation (EU) 2024/2847 (Cyber Resilience Act), C/2026/6013 ↗
Primary source for this page — Commission notice, published in the Official Journal (C series) on 17 November 2026; in particular Sections 2, 4, 5, 7, 8 and 9; not binding
European Parliament and Council of the EU · 2024
Regulation (EU) 2024/2847 on horizontal cybersecurity requirements for products with digital elements (Cyber Resilience Act) ↗
Legal basis — in particular Art. 3, 13, 14, 26, 69 and Annex I
European Commission · 2024
Commission Implementing Regulation (EU) 2024/2690 laying down rules for the application of Directive (EU) 2022/2555 (NIS2) as regards technical and methodological requirements of cybersecurity risk-management measures ↗
Evidence for cloud providers (para. 207) and reference point for the notion of becoming aware (para. 212)
European Parliament and Council of the EU · 2022
Directive (EU) 2022/2555 on measures for a high common level of cybersecurity across the Union (NIS2 Directive) ↗
European vulnerability database under Art. 12(2) (para. 233); cloud services in scope (para. 183)
European Parliament and Council of the EU · 2022
Regulation (EU) 2022/2554 on digital operational resilience for the financial sector (DORA) ↗
Evidence for third-party services (para. 207)
European Parliament and Council of the EU · 2019
Regulation (EU) 2019/881 (Cybersecurity Act) ↗
European cybersecurity certification schemes as evidence (para. 207)
European Commission · 2022
Commission Delegated Regulation (EU) 2022/30 supplementing Directive 2014/53/EU (Radio Equipment Directive) ↗
Continued validity of existing certificates under Art. 69(1) CRA (paras. 251–254)
European Parliament and Council of the EU · 2023
Regulation (EU) 2023/1230 on machinery (Machinery Regulation) ↗
Cyber-safety requirements and continued validity of certificates (paras. 255–257)
European Parliament and Council of the EU · 2019
Regulation (EU) 2019/2144 on type-approval requirements for motor vehicles ↗
Exclusion for vehicle components (paras. 241–246)
European Commission · 2022
Commission Notice — The ‘Blue Guide’ on the implementation of EU product rules 2022 ↗
Basis for placing on the market and modifications of products (Guidance 2.1 and 4.4)
Embedding CRA requirements in your architecture and pipeline?
VamiSec supports engineering and product security teams in delineating the product and its remote data processing, with risk assessment and threat modelling, component due diligence and SBOMs, release criteria for substantial modifications, and building PSIRT and reporting processes — as implementation support, not as conformity assessment or legal advice.