IEC 62443-4-1 assesses the organization: is there a documented development process, applied in practice, that embeds security from requirements through to end of support? IEC 62443-4-2 assesses the product: which security capabilities does a specific component in a specific version provide? Part 4-2 presupposes the 4-1 process — security functions alone are not enough. The cross-industry framework is described on the product security page.
Product security at a glance →IEC 62443-4-1 and -4-2 for manufacturers of industrial components
What IEC 62443-4-1 requires of the secure development process and IEC 62443-4-2 of the individual component — with practices, maturity levels, foundational requirements, security levels, certificates, the CRA context and a roadmap for manufacturers.
Last updated: November 2026 · Valeri Milke, ISO 27001 & ISO 42001 Lead Auditor
8practices make up the secure development process under IEC 62443-4-1:2018 — from SM to SG
47requirements are spread across these eight practices, from SM-1 to SG-7 (2018 edition)
7foundational requirements (FR 1–7) structure the component requirements of IEC 62443-4-2:2019
SL 1–4security levels — from casual violations to attackers with extended resources
IEC 62443-4-1 specifies how manufacturers develop and maintain industrial products securely; IEC 62443-4-2 specifies which technical security capabilities an individual component of an industrial automation and control system (IACS) must provide. Both parts are aimed at product suppliers — manufacturers of controllers, field and network devices, industrial PCs and software. Part 4-1 describes the lifecycle in eight practices with 47 requirements, from the threat model and testing to vulnerability handling, updates and security guidelines. Part 4-2 assigns its requirements to seven foundational requirements and four component types and grades them by security levels 1 to 4. This page explains both parts from the manufacturer’s perspective and clearly delineates certificates and legal obligations; the asset owner’s perspective is covered on the OT security page.
From standard to market obligation
Milestones for manufacturers of industrial components — tap an entry for details.
January 15, 2018
IEC 62443-4-1 is published
The requirements for the secure product development lifecycle are published; CENELEC adopts them unchanged in February 2018.
February 27, 2019
IEC 62443-4-2 is published
The technical security requirements for IACS components are published; adopted as an EN in April 2019, with a corrigendum in 2022.
December 10, 2024
Cyber Resilience Act enters into force
The Cyber Resilience Act enters into force and sets requirements for products with digital elements — including industrial components.
March 2026
Draft EN amendments to 4-1 and 4-2
CENELEC presents drafts to align both parts with the CRA; the enquiry ran until June 5, 2026. As of November 2026, no amendment has been published.
September 11, 2026
CRA reporting obligations apply
Manufacturers report actively exploited vulnerabilities and severe incidents via the ENISA platform, with an early warning within 24 hours.
January 20, 2027
Machinery Regulation applies
The EU Machinery Regulation replaces the Machinery Directive and requires protection against corruption and against malicious interference with control systems.
December 11, 2027
All CRA obligations apply
Essential requirements, conformity assessment and CE marking under the CRA apply as well; the cybersecurity rules of the Radio Equipment Directive end.
Key points at a glance
Eight key messages — tap to expand.
The series distributes responsibility among asset owners, integration and maintenance service providers, and product suppliers. For product suppliers, the ISA Global Cybersecurity Alliance names Parts 4-1, 4-2, 3-3 and 3-2. Manufacturers develop in line with 4-1 regardless of where the product will be used; integrators use these products to build the automation solution in line with 2-4 and 3-2, and asset owners operate it in line with 2-1. The asset owner’s perspective is covered on the OT security page.
Asset owner’s view: OT security →Part 4-1 structures the secure development lifecycle into eight practices with 47 requirements — from security management through requirements, design, implementation and testing to vulnerability handling, updates and security guidelines. It applies to hardware, software and firmware until the end of the product’s life. At the heart of the requirements phase is a threat model for each product that is kept up to date throughout the lifecycle. How robust threat models are built is explained on the threat modeling page.
Go to threat modeling →Part 4-2 derives its component requirements (CRs) from the system requirements of IEC 62443-3-3 and assigns them to seven foundational requirements — from identification and authentication control to resource availability. It distinguishes software applications, embedded devices, host devices and network devices, with type-specific requirements (SAR, EDR, HDR, NDR). Requirement enhancements (REs) extend a requirement for higher security levels; Annex B of the standard maps everything to levels 1 to 4.
Security levels describe attacker profiles — from casual or coincidental violations (SL 1) to targeted attacks using sophisticated means, extended resources and high motivation (SL 4). Part 4-2 defines only a component’s capability, the capability security level (SL-C). The asset owner sets the target level (SL-T) for each zone; the achieved level (SL-A) emerges in operation. A manufacturer can demonstrate an SL-C, but cannot promise the level of protection of a plant.
Both the 4-1 process and 4-2 components can be certified, for example through ISASecure SDLA and CSA or within the IEC’s IECEE system. A 4-1 certificate confirms a specific, versioned process, where applicable with a maturity level; a 4-2 certificate confirms the SL-C of a specific component and version. It proves neither the level of protection of a plant nor properties of other products — nor conformity with the Cyber Resilience Act. Check the scope, version and declared claims.
Neither the Cyber Resilience Act (CRA) nor the Commission’s guidance mentions IEC 62443. A standard only gives rise to a presumption of conformity if it is cited as a harmonized standard in the Official Journal of the EU; as of November 2026, this applies to no standard in the IEC 62443 series, and the CRA-related EN amendments are drafts. Nevertheless, a 4-1 process applied in practice provides solid building blocks for risk assessment, vulnerability handling, security updates and technical documentation.
Go to the Cyber Resilience Act →From January 20, 2027, the EU Machinery Regulation requires safety-related software, data and control systems to be protected against corruption and malicious interference — without mentioning IEC 62443. Entities under NIS2 take into account their suppliers’ cybersecurity practices, including secure development procedures. Proof of 4-1 compliance and a 4-2 SL-C are therefore natural evidence to present to customers. More on this on the supply chain security page.
Go to supply chain security →Four component types in IEC 62443-4-2
Common requirements (CRs) apply to all types, type-specific requirements supplement them — select a type.
SAR · 2 requirements
- Programs, including their dependencies, that interact with the process or the control system.
- Two type-specific requirements; missing capabilities can be provided by a higher-level entity, such as central authentication.
SARCRAllocation
EDR · 8 requirements
- Special-purpose device that directly monitors or controls an industrial process, such as a PLC.
- Eight type-specific requirements, for example on updates and boot integrity; essential functions take priority.
EDRPLCUpdatesBoot integrity
HDR · 8 requirements
- General-purpose device with an operating system that can host applications, data or functions from several vendors.
- Eight type-specific requirements; the manufacturer documents updates for the operating system and third-party components in line with 4-1.
HDROperating systemSUM-3
NDR · 12 requirements
- Device that facilitates or restricts the flow of data between devices.
- Twelve type-specific requirements; under the CRA, routers, switches, VPN products and firewalls fall into the categories of important products.
NDRSwitchVPNFirewall
Interactive
Which parts of IEC 62443 apply to you?
Up to three yes/no questions lead from your role to the relevant parts of the series; if you have several roles, check each one separately. Orientation, not legal advice.
Your path
- 1?
1: Do you develop or maintain hardware, software or firmware for industrial automation and control systems?
1
Do you develop or maintain hardware, software or firmware for industrial automation and control systems?
For example controllers, field devices, network components or engineering software. If you only resell or integrate third-party products: No.
IEC 62443-4-1 for your process, IEC 62443-4-2 for each component
As a component manufacturer, you are the core target group of both parts: Part 4-1 governs the development process, Part 4-2 the technical capabilities of each component. Because 4-2 presupposes a 4-1 process, start with the process and then assign a component type and a target SL-C to each product.
- Carry out a gap analysis against the 47 requirements of 4-1, including the maturity level.
- Align the target SL-C for each product with your customers’ operating environments.
- Check the CRA classification based on core functionality; reporting obligations have applied since September 11, 2026.
IEC 62443-4-1IEC 62443-4-2SL-C
Control systems: process under 4-1, system capabilities under 3-3
If you supply complete control systems as a product, you also develop in line with IEC 62443-4-1. The system’s capabilities are described in IEC 62443-3-3 along the same seven foundational requirements; it defines the SL-C of the control system. For the components used, 4-2 remains the benchmark.
- Establish a development process in line with 4-1 and assess its maturity level.
- State the system’s SL-C under 3-3 and select suitable components under 4-2.
- Part 2-4 applies to additional integration or maintenance services.
IEC 62443-3-3IEC 62443-4-1
Manufacturer and service provider at once: keep the roles separate
You develop your own products and also provide integration, commissioning or service. Your products are subject to IEC 62443-4-1 and, for each component, to 4-2; integration and maintenance are subject to the service provider requirements of IEC 62443-2-4. What matters is a clear allocation of what is a product and what is a service.
- Split the portfolio: product (4-1, 4-2, 3-3) or service (2-4)?
- Review reused control and software modules as products.
- Plan for the cybersecurity requirements of the Machinery Regulation from January 20, 2027.
IEC 62443-2-4Machinery Regulation
Integration and maintenance: IEC 62443-2-4 and 3-2 instead of 4-1
IEC 62443-4-1 explicitly does not apply to integrators. What counts are the service provider requirements of IEC 62443-2-4 and the risk assessment with zones and conduits under IEC 62443-3-2, in which you can support the asset owner. If you combine components into control systems, you use 3-3; 4-2 serves as a procurement benchmark.
- Build a security program for integration and maintenance in line with 2-4.
- Define the target level for each zone together with the asset owner.
- Procure components with a suitable SL-C and configure them according to the manufacturers’ guidelines.
IEC 62443-2-4IEC 62443-3-2
Asset owners: security program under 2-1, risk assessment under 3-2
As an asset owner, you remain responsible for the security of your plants, even when service providers are involved. What counts are the security program under IEC 62443-2-1 and the risk assessment with zones, conduits and target security levels under IEC 62443-3-2. You use Parts 4-1 and 4-2 as requirements for suppliers.
- Derive the target level for each zone from the risk assessment.
- Require proof of 4-1 compliance and a 4-2 SL-C in tenders.
- Check certificates for scope, version, level and claims.
IEC 62443-2-1IEC 62443-3-2
No direct relevance — but check your customers and products
If you neither develop products for industrial automation nor integrate, maintain or operate plants, IEC 62443 does not apply to you directly. It becomes relevant as soon as customers use your products in control systems and ask for evidence along the lines of the series.
- Check whether your products are used in industrial environments.
- Check the CRA obligations for products with digital elements independently of this.
- Use the product security fundamentals as a starting point.
Supply chainCRA
- Do you develop or maintain hardware, software or firmware for industrial automation and control systems?
- Do you supply individual components that customers build into their own systems?
- Do you also provide integration, commissioning or maintenance at customer sites?
- Do you design, integrate or maintain automation solutions as a service provider for asset owners?
- Do you operate industrial plants yourself and are you responsible for their control systems?
Deep dive
IEC 62443-4-1 and -4-2 in eight chapters
From the series of standards through the eight practices of 4-1 and the requirements of 4-2 to security levels, the supply chain, certificates, the CRA, the Machinery Regulation and NIS2 — with a roadmap and typical gaps at the end.
The IEC 62443 series and the manufacturer’s role
IEC 62443 is a series of standards for the security of industrial automation and control systems that assigns obligations by role. For manufacturers, Parts 4-1 and 4-2 are the most relevant.
The series is developed jointly by the ISA99 committee and IEC Technical Committee TC 65; the ISA and IEC editions have identical content. As the series understands it, an IACS comprises personnel, hardware, software and policies. The main groups:
- General (TS 62443-1-1): terminology, concepts, models
- Policies and procedures (2-1, 2-4): the asset owner’s security program, requirements for service providers
- System (3-2, 3-3): risk assessment with zones and conduits, system requirements
- Component (4-1, 4-2): secure development process, technical component requirements
- Evaluation (TS 62443-6-2): evaluation methodology for components under 4-2
Four roles, shared responsibility
Asset owner (operator)
Is accountable for and operates the IACS and passes requirements on into the supply chain.
Integration service provider
Designs, installs, configures, tests and hands over the solution.
Maintenance service provider
Maintains and supports the solution in operation.
Product supplier
Develops and supports systems, devices and software.
For product suppliers, the ISA Global Cybersecurity Alliance lists Parts 4-1, 4-2, 3-3 and 3-2 as applicable. Part 4-1 applies to the developers and maintainers of a product, not to integrators or users; service providers that supply their own products take on the manufacturer role to that extent. The valid editions are 4-1:2018 and 4-2:2019, adopted unchanged by CENELEC; no new edition had been published by November 2026.
IEC 62443-4-1: eight practices and four maturity levels
IEC 62443-4-1 requires a documented development lifecycle, applied in practice, with eight practices and 47 requirements. It governs how products are developed — not which security functions a product has.
The requirements apply to hardware, software and firmware until the end of the product’s life. The standard is largely based on the ISA Security Compliance Institute’s requirements for SDLA certification; its only normative reference is to IEC 62443-2-4.
| Practice | Requirements | What is expected |
|---|---|---|
| Security management (SM) | 13 | Versioned process, roles, competence; protection of the development environment and keys; requirements for externally supplied components; process verification |
| Specification of security requirements (SR) | 5 | Security context, threat model for each product, reviewed requirements |
| Secure by design (SD) | 4 | Design principles, defense in depth, design reviews |
| Secure implementation (SI) | 2 | Coding guidelines, implementation reviews |
| Security verification and validation testing (SVV) | 5 | Testing of security functions and countermeasures, vulnerability and penetration testing including fuzzing, independent testers |
| Management of security-related issues (DM) | 6 | Receive, assess, fix and disclose reports |
| Security update management (SUM) | 5 | Qualify and document updates, deliver them authentically and promptly |
| Security guidelines (SG) | 7 | Defense-in-depth concept, measures in the environment, hardening, operation, accounts, decommissioning |
Identifiers SM-1 to SG-7 (2018 edition), our own summary. The standard sets out the independence of testers in a separate table.
Maturity levels: how well the process is applied in practice
| Maturity level | Characteristics according to the ISA Global Cybersecurity Alliance |
|---|---|
| 1 · Initial | Development mostly ad hoc and often undocumented |
| 2 · Managed | Written guidance, trained staff, defined processes — some not yet applied in practice |
| 3 · Defined (Practiced) | All processes repeatable and demonstrably applied in practice |
| 4 · Improving | CMMI levels 4 and 5 combined: process metrics and continuous improvement |
Maturity levels assess processes, security levels assess technology; a mature process can produce a component with SL-C 1. Parts 2-1, 2-2 and 2-4 also use maturity levels, and one publicly viewable IECEE certificate for 4-1 states a maturity level. Level 3 is a sensible first goal: only at this level is a process considered demonstrably applied in practice.
IEC 62443-4-2: foundational requirements, component types and enhancements
IEC 62443-4-2 describes the technical security capabilities of a component. It assigns its requirements to seven foundational requirements and distinguishes four component types.
The component requirements (CRs) are derived from the system requirements of IEC 62443-3-3. Manufacturers use them to determine what a component needs for a given SL-C; integrators use them to procure components that match the target level of a zone.
| Foundational requirement | CRs | Examples |
|---|---|---|
| FR 1 · Identification and authentication control | 1.1–1.14 | User authentication, password strength |
| FR 2 · Use control | 2.1–2.13 | Authorizations, auditable events |
| FR 3 · System integrity | 3.1–3.14 | Integrity of communication and software, updates, boot process |
| FR 4 · Data confidentiality | 4.1–4.3 | Cryptography |
| FR 5 · Restricted data flow | 5.1–5.4 | Network segmentation |
| FR 6 · Timely response to events | 6.1–6.2 | Continuous monitoring |
| FR 7 · Resource availability | 7.1–7.8 | DoS protection, backup, least functionality, component inventory |
58 CR numbers according to the 2019 edition; examples paraphrased.
| Component type | Type-specific requirements |
|---|---|
| Software application | SAR · 2 |
| Embedded device, such as a PLC | EDR · 8 |
| Host device with a general-purpose operating system | HDR · 8 |
| Network device | NDR · 12 |
| Element of a CR | Function |
|---|---|
| Requirement | Baseline capability of the component |
| Rationale | Purpose and background of the requirement |
| Requirement enhancements (REs) | Additional capabilities for higher security levels |
| Security level mapping | Which combination of CR and REs is needed for SL 1 to 4; full overview in Annex B |
Only the CR together with the REs it meets determines the SL-C of a component. Four overarching constraints apply: support of essential functions, compensating countermeasures, least privilege and a development process in line with IEC 62443-4-1.
The draft EN amendments would delete the type-specific clauses; the 2019 edition remains authoritative.
Security levels: from the component’s SL-C to the plant’s SL-A
Security levels describe the attacker profiles a system is designed to withstand. IEC 62443-4-2 only covers the capability of the component (SL-C); target and achieved levels only emerge in the plant.
A security level measures the confidence that a system, zone or conduit is free of vulnerabilities and functions as intended.
| Level | Attacker profile |
|---|---|
| SL 1 | casual or coincidental violations |
| SL 2 | intentional, simple means, low resources, generic skills, low motivation |
| SL 3 | intentional, sophisticated means, moderate resources, IACS-specific skills, moderate motivation |
| SL 4 | intentional, sophisticated means, extended resources, IACS-specific skills, high motivation |
| View | Who sets it? | Meaning |
|---|---|---|
| SL-C · Capability | Manufacturer | What the system (3-3) or component (4-2) natively achieves when properly integrated |
| SL-T · Target | Asset owner | Target for each zone and conduit from the risk assessment under 3-2 |
| SL-A · Achieved | results from operation | Level of protection actually achieved in the plant |
From component to plant
- 14-1 · 4-2 · 3-3Develop
Manufacturers develop in line with 4-1 and state the SL-C — under 4-2 for components, under 3-3 for systems.
- 23-2Set the target
The asset owner divides the plant into zones and conduits and sets an SL-T for each zone.
- 32-4Integrate
The integrator procures components that match the SL-T and configures them according to the manufacturers’ guidelines.
- 42-1 · 2-4Operate
Operation, patching and monitoring determine which SL-A is achieved.
A plant therefore does not automatically reach SL 3 just because it contains a component with SL-C 3. Capabilities may be allocated to a higher-level entity, such as central authentication; the security guidelines under 4-1 describe how the target level is reached. Integrators that combine components into control systems use 3-3.
Essential functions take priority: the safety function, control and the ability of operating personnel to view and intervene in the process — access control must not block them. Since January 2025, IEC TS 62443-6-2 has described how evaluations are carried out; it is not a certification scheme and presupposes a 4-1 process.
Certification under IEC 62443-4-1 and -4-2: programs and significance
Certificates under IEC 62443-4-1 and -4-2 confirm a process or a component within a precisely defined scope. They are voluntary and do not replace a statutory conformity assessment.
Among other options, two routes are open to manufacturers: ISASecure, run by the non-profit ISA Security Compliance Institute with certification bodies accredited to ISO/IEC 17065, and the IEC’s IECEE system.
| Program | Subject | Result |
|---|---|---|
| ISASecure SDLA | Development process under 4-1 | Specific process version; prerequisite for CSA and SSA |
| ISASecure CSA | Component under 4-2 and 4-1 | Component type and capability level 1 to 4 |
| ISASecure SSA | Control system under 3-3 | System capabilities, development in line with SDLA |
| IECEE | Process or product | Certificate of conformity “Industrial Cyber Security Capability” for the declared claims |
Also available: ICSA for IIoT components, HCSA, and ACSSA for asset owners’ sites; in 2019, CSA replaced the older EDSA.
What a certificate proves — and what it doesn’t
| A certificate proves … | … but not |
|---|---|
| for 4-1, a specific, versioned process, where applicable with a maturity level | that every product of the manufacturer meets 4-2 |
| for 4-2, the SL-C of a specific component and version | the achieved level of protection (SL-A) of a plant |
| assessment by an independent certification body | a presumption of conformity under the CRA or CE marking |
Review supplier certificates as you would a contract: organization, process or product, version, level, claims, expiry date. It makes sense to establish a process applied in practice first and only then decide on a certificate for the process or for lead products.
IEC 62443-4-1 and -4-2 under the Cyber Resilience Act
The Cyber Resilience Act does not mention IEC 62443, and no standard in the series is cited as a harmonized standard. Nevertheless, 4-1 and 4-2 provide a solid framework for implementing the CRA obligations.
Since September 11, 2026, manufacturers have been reporting actively exploited vulnerabilities and severe security incidents via ENISA’s reporting platform to the coordinating CSIRT and to ENISA: an early warning within 24 hours, a notification within 72 hours, and a final report 14 days after a remedy becomes available, or after one month for incidents — including for products already on the market. All other obligations apply from December 11, 2027; a 4-1 process applied in practice supports many of them.
| CRA obligation | Counterpart in 4-1 |
|---|---|
| Risk assessment in the technical documentation | SR-1 to SR-5 |
| Due diligence for third-party components | SM-9, SM-10; plus SBOM |
| Secure default settings, security testing | SD-1 to SD-4, SG-3, SVV-1 to SVV-5 |
| Vulnerability handling, coordinated disclosure | DM-1 to DM-6; plus CRA reporting channels |
| Security updates, user information | SUM-1 to SUM-5, SG-1 to SG-7 |
Our own mapping; meeting 4-1 does not give rise to a presumption of conformity.
A standard only gives rise to a presumption of conformity if it is cited as a harmonized standard with its reference in the Official Journal; according to the sources available, none had yet been cited for the CRA by mid-November 2026. The lists of important and critical products do not contain a separate category for controllers or PLCs — what matters is the core functionality: routers, switches, VPN products, operating systems and network interfaces belong to Class I, firewalls and intrusion detection systems to Class II. According to the regulation, industrial control systems are often in use for considerably longer; manufacturers should therefore set the support period of at least five years realistically.
Draft amendments to 4-1 and 4-2
The drafts from March 2026 are intended to align both parts with the CRA: among other things, the 4-1 draft adds a practice on security risk management, a secure-by-default requirement and mappings to prEN 40000-1-2 and -1-3; the 4-2 draft introduces a complete evaluation methodology. Whether they will be cited is open — the work program for the standardization request lists them as supporting OT documents, not among the requested standards.
Machinery Regulation, NIS2 and radio equipment: why customers ask about IEC 62443
Neither the Machinery Regulation nor the NIS2 Directive mentions IEC 62443. Both nevertheless create a pull, because they demand outcomes that manufacturers can demonstrate in a structured way with 4-1 and 4-2.
| Legislation | Applies | Role of IEC 62443 |
|---|---|---|
| Cyber Resilience Act | Reporting obligations since September 11, 2026, otherwise from December 11, 2027 | not mentioned, not harmonized |
| EU Machinery Regulation | from January 20, 2027 | not mentioned; established implementation route |
| NIS2; in Germany, the BSI Act (BSIG) | BSI Act since December 6, 2025 | not mentioned; evidence for customers |
| Cybersecurity requirements of the Radio Equipment Directive, EN 18031 | since August 2025, no longer apply from December 11, 2027 | none directly; only covered radio equipment |
Machinery Regulation
From January 20, 2027, the EU Machinery Regulation applies to machinery newly placed on the market. Connecting it or accessing it remotely must not create a hazard; safety-related software, data and signal-carrying hardware must be protected against corruption, interventions must be logged and the software needed for safe operation must be identified. Control systems must withstand foreseeable malicious attempts by third parties; interventions and uploaded versions of the safety software must be recorded for five years.
The regulation provides for a presumption of conformity via European cybersecurity certification schemes, among other routes — ISASecure and IECEE certificates are not among them. Meeting the CRA can help, but both conformity assessments remain necessary. For control systems and safety software, 4-1 and the foundational requirements of 4-2 are an established route to implementation.
NIS2 and radio equipment
In the manufacturing sector, NIS2 covers manufacturers of electronics, electrical equipment, machinery, vehicles and medical devices, among others; in addition, regulated entities take into account their suppliers’ cybersecurity practices, including secure development procedures — proof of 4-1 compliance is an obvious piece of evidence for this. The cybersecurity requirements of the Radio Equipment Directive with EN 18031 only concern covered radio equipment and no longer apply from December 11, 2027; details on the product security page.
Roadmap: implementing IEC 62443-4-1 and -4-2 in your company
Implementation starts with the role and a gap analysis, not with a certificate. It makes sense to build the process first and then bring the products into line one by one.
The roadmap is a recommendation, not a requirement of the standard; each step is tied to requirements of 4-1 or 4-2.
- 1ScopeClarify role and legal framework
Separate components (4-2), systems (3-3) and services (2-4); check the CRA and the Machinery Regulation.
- 2GapGap analysis
Assess the process against the 47 requirements, including the maturity level, and products against the CRs and REs of the target SL-C.
- 3SMSet up the process
Roles, a protected development environment, key management, requirements for externally supplied components.
- 4SRThreat model for each product
Document the security context, threats, target SL-C and CRA risk assessment.
- 5SD · SI · SVVDevelop and test
Defense in depth, secure default settings, coding guidelines, fuzzing, penetration tests with independent testers.
- 6DM · SUM · SGPSIRT, updates, guidelines
Reporting channel including CRA notifications, authentic updates, an SBOM for each release, hardening and integration guidance.
- 7EvidenceEvidence and standardization
Decide on SDLA, CSA or IECEE once the process is applied in practice; keep track of the drafts and EN 40000.
Typical gaps
| Gap | Reference | Remedy |
|---|---|---|
| No documented security context | SR-1, SG-2 | Define deployment assumptions and environmental measures |
| Threat model only at project start | SR-2 | Update it with every significant change |
| Unprotected signing keys | SM-7, SM-8 | Manage them securely, log access |
| Penetration tests without defined independence | SVV-4, SVV-5 | Define the required independence |
| No reporting channel for vulnerabilities | DM-1 to DM-5 | Set up a point of contact and a PSIRT process |
VamiSec supports manufacturers with gap analyses against IEC 62443-4-1 and -4-2, threat modeling for each product and product penetration tests — in preparation for customer requirements, the CRA and possible certification. The free IEC 62443 self-assessment (link in the sources) provides a first overview; it is not an audit.
Glossary
Glossary: terms used in IEC 62443-4-1 and -4-2
12 terms from the process standard and the component standard, briefly explained — in the original English wording of the standards, with the German equivalent.
12 of 12 terms
- IACSIndustrielles Automatisierungs- und Steuerungssystem
- Industrial automation and control system. IEC 62443 includes the personnel, hardware, software and policies that can affect the safe and secure operation of an industrial process.
- Secure development lifecycle (SDL)Sicherer Entwicklungslebenszyklus
- A structured process that integrates security into every phase of product development, from requirements to the end of the product’s life. IEC 62443-4-1 describes it in eight practices.
- Product security contextProdukt-Sicherheitskontext
- Definition of the environment in which, and the assumptions under which, a product is used. First requirement of practice SR in IEC 62443-4-1 and the basis of the threat model.
- Maturity level (ML)Reifegrad
- Assessment of how well established a process is: Initial, Managed, Defined (Practiced) and Improving. Maturity levels assess processes, not technology; they are used in Parts 2-1, 2-2, 2-4 and 4-1.
- Foundational requirement (FR)Grundanforderung
- One of the seven categories in IEC 62443-3-3 and -4-2: identification and authentication control, use control, system integrity, data confidentiality, restricted data flow, timely response to events, resource availability.
- Component requirement (CR)Komponentenanforderung
- A technical requirement in IEC 62443-4-2 that applies to all four component types, such as CR 1.1 on human user authentication. Type-specific requirements are called SAR, EDR, HDR or NDR.
- Requirement enhancement (RE)Anforderungserweiterung
- An addition to a requirement that is needed for higher security levels. Only the base requirement together with the enhancements met determines the capability security level of a component.
- Security levelSL 1–4
- A measure of confidence that a system, zone or conduit is free of vulnerabilities and functions as intended. The four levels describe attacker profiles, not guarantees.
- SL-C, SL-T and SL-ACapability, target and achieved security level
- SL-C is the capability of a system or component when properly integrated, SL-T the target level from the asset owner’s risk assessment, SL-A the level achieved in operation. Part 4-2 only defines SL-C.
- Essential functionsWesentliche Funktionen
- Functions that safeguard health, safety, the environment and the availability of the plant: the safety function, the control function, and the operating personnel’s ability to view and intervene. Protective measures must not impair them.
- ISASecure SDLA and CSAISASecure certification programs
- Programs of the ISA Security Compliance Institute: SDLA for the development process under IEC 62443-4-1, CSA for components under IEC 62443-4-2 including the process; certification bodies accredited to ISO/IEC 17065.
- Harmonized standardHarmonisierte Norm
- A European standard developed at the request of the Commission whose reference is published in the Official Journal of the EU. Applying it gives rise to a presumption of conformity for the requirements it covers; no standard in the IEC 62443 series is cited in this way under the CRA.
FAQ
Frequently asked questions about IEC 62443-4-1 and -4-2
Short answers for manufacturers of industrial components — as of November 2026, not legal advice.
IEC 62443-4-1 governs the process, IEC 62443-4-2 the product. Part 4-1 sets out, in eight practices with 47 requirements, how manufacturers develop securely, test, handle vulnerabilities and deliver updates. Part 4-2 specifies which security capabilities a component provides for each security level, and it presupposes a 4-1 process.
IEC 62443-4-1 applies to companies that develop and maintain hardware, software or firmware for industrial automation and control systems, from individual components to control systems. It explicitly does not apply to integrators and users; for them, Parts 2-4, 3-2 and 2-1 are the main reference points.
Yes. IEC 62443-4-2 contains a normative reference to 4-1 and requires a development process in line with 4-1 as an overarching constraint. ISASecure CSA also assesses the process, and the evaluation methodology IEC TS 62443-6-2 presupposes it. Security functions alone are not enough.
IEC 62443-4-2 defines software applications, embedded devices such as programmable logic controllers, host devices with a general-purpose operating system, and network devices. Common requirements are called CRs; type-specific requirements are labeled SAR (two), EDR (eight), HDR (eight) and NDR (twelve).
The standard does not prescribe a fixed level. Manufacturers state a capability security level (SL-C); the level a plant needs is set by the asset owner as a target level (SL-T) for each zone. Align your target SL-C with your customers’ typical operating environments and describe in the security guidelines what the environment must add.
No. As of November 2026, no standard in the IEC 62443 series is cited in the Official Journal of the EU as a harmonized standard for the CRA. The European amendments to 4-1 and 4-2 with a CRA link are drafts, and whether they will be cited later is open. A presumption of conformity therefore does not arise — but the standard is still a solid framework for implementing the CRA.
No. Neither the Cyber Resilience Act nor the Machinery Regulation, the NIS2 Directive or the Commission’s CRA guidance mentions IEC 62443. They demand outcomes such as protection against corruption, vulnerability handling or secure development procedures in the supply chain — Parts 4-1 and 4-2 are an established way to achieve and demonstrate these outcomes.
No. IEC 62443-4-1:2018 and IEC 62443-4-2:2019 remain valid. A second IEC edition of 4-1 is in preparation, and at European level, draft amendments to both parts have been available since March 2026. No new edition had been published by November 2026; drafts may still change.
A 4-1 certificate confirms a specific, versioned development process, where applicable with a maturity level; a 4-2 certificate confirms the SL-C of a specific component and version. It proves neither the level of protection of a plant nor properties of other products, nor CRA conformity. Check the scope, version, level and declared claims.
Standards & Sources
The content on this page is based on the following publicly available guides and studies.
IEC · 2018
IEC 62443-4-1:2018 – Secure product development lifecycle requirements ↗
Edition 1.0 of January 15, 2018; eight practices, 47 requirements (SM-1 to SG-7), maturity levels.
IEC · 2019
IEC 62443-4-2:2019 – Technical security requirements for IACS components ↗
Edition 1.0 of February 27, 2019, corrigendum 2022; FR 1–7, CR 1.1–7.8, SAR/EDR/HDR/NDR, CCSC, Annex B.
IEC · 2025
IEC TS 62443-6-2:2025 – Security evaluation methodology for IEC 62443-4-2 ↗
January 21, 2025; evaluation methodology, not a certification scheme, presupposes 4-1.
CENELEC (sample pages via iTeh) · 2026
EN IEC 62443-4-1:2018/prAA:2026 – Draft amendment ↗
Draft of March 2026, enquiry until June 5, 2026: practice Security risk management, SD-5 Secure by default, mappings to prEN 40000-1-2/-1-3.
CENELEC (sample pages via iTeh) · 2026
EN IEC 62443-4-2:2019/prAA:2026 – Draft amendment ↗
Draft of March 2026: evaluation methodology, deletion of clauses 12–15, CR 7.9 Component reset, Annex ZZ.
European Parliament and Council · 2024
Regulation (EU) 2024/2847 (Cyber Resilience Act) ↗
Art. 13(2)–(5) and (8), Art. 14, Art. 27(1), Annexes I and III; recitals 53 and 60.
European Commission · 2026
Guidance on the application of Regulation (EU) 2024/2847, C/2026/6013 ↗
Official Journal of November 17, 2026, non-binding; industrial examples 39, 55 and 56.
European Parliament and Council · 2023
Regulation (EU) 2023/1230 (Machinery Regulation) ↗
Applies from January 20, 2027; Annex III, sections 1.1.9 and 1.2.1; Art. 20(9).
European Parliament and Council · 2022
Directive (EU) 2022/2555 (NIS2 Directive) ↗
Annex II (manufacturing); Art. 21(2)(d) and (e), Art. 21(3). In Germany: BSI Act (BSIG) since December 6, 2025.
European Commission · 2026
Radio Equipment Directive (RED) – topic page ↗
Delegated Regulation (EU) 2022/30 since August 2025, repealed by (EU) 2026/339 with effect from December 11, 2027; EN 18031 cited with restrictions.
CEN, CENELEC and ETSI · 2025
Work Programme M/606 (Cyber Resilience Act), Version 1 ↗
April 2, 2025; 62443 amendments as supporting OT documents.
ISA Security Compliance Institute · 2026
ISASecure Certification ↗
SDLA, CSA, ICSA, SSA, HCSA, ACSSA; certification bodies accredited to ISO/IEC 17065.
ISA Security Compliance Institute · 2026
ISASecure IEC 62443 SDLA Certification ↗
Named organization, specific process version; prerequisite for CSA and SSA; time-limited.
ISA Security Compliance Institute · 2026
ISASecure IEC 62443 CSA Certification ↗
Four component types, capability levels 1–4; CSA 1.0.0 since August 28, 2019, successor to EDSA.
IECEE · 2026
IECEE – IEC standards in the Cyber Security (CYBR) category ↗
Lists IEC 62443-4-1:2018 and IEC 62443-4-2:2019, among others.
ISA Global Cybersecurity Alliance (ISAGCA) · 2024
Security of Industrial Automation and Control Systems – An Overview of ISA/IEC 62443 Standards ↗
Roles, security levels, SL-C/-T/-A, maturity levels, component types, essential functions.
VamiSec · 2026
IEC 62443 self-assessment ↗
Free self-assessment for asset owners, systems and manufacturers; not an audit, not a conformity assessment.
Where do your process and components stand?
In a no-obligation initial consultation, we classify your role and portfolio and show where your development process and components stand against IEC 62443-4-1 and -4-2 — with a view to customer requirements, the CRA and the Machinery Regulation.