What happened in the cyberattacks on refrigeration systems?+
Overnight into October 12, 2026, unknown actors manipulated the refrigeration controllers of hundreds of French supermarkets; the government cited around 700 stores. Overnight into November 2, a second wave followed, with more than 100 affected stores in more than a dozen European countries, including Germany and Switzerland. Refrigerated units were put into defrost mode and setpoints raised; goods spoiled.
How did the attackers get into the refrigeration systems?+
Based on current information, they got in through controllers that were directly reachable from the internet, mainly Danfoss system managers of the AK-SM and AK-SC series as well as Copeland and Dixell XWEB supervisors. Unchanged default passwords have been documented in several cases; with outdated firmware, known flaws are a possible route. No malware was used.
Who is behind the attacks?+
That remains unclear. A channel of the pro-Russian group NoName057(16) has claimed responsibility for the attacks together with Z-Pentest, but there is no evidence for this. No government or authority has named a perpetrator; the Kremlin denies involvement.
Were Germany and Switzerland also affected?+
Yes. In Germany, the police are investigating several cases, including in North Rhine-Westphalia, Lower Saxony, Bavaria and Rhineland-Palatinate; the BSI has confirmed isolated incidents at supermarkets. In Switzerland, a butcher’s shop in Köniz and three Volg branches were hit.
Do supermarkets fall under NIS2?+
Food retail as such does not. In the food sector, NIS2 covers wholesale and industrial production and processing; it also covers healthcare and many branches of industry, including manufacturers of refrigeration and control technology. In Germany, however, large retail companies can still be covered via the critical-infrastructure (KRITIS) thresholds.
What does the Cyber Resilience Act have to do with the attacks?+
The CRA requires manufacturers of connected products, including refrigeration controllers, to provide a secure default configuration, protection against unauthorized access, security updates throughout the support period and structured vulnerability management. These requirements apply from December 11, 2027. The reporting obligations for actively exploited vulnerabilities, however, have applied since September 11, 2026, including for older products.
Do manufacturers have to report such incidents?+
Under the CRA, manufacturers must report actively exploited vulnerabilities and severe incidents: early warning within 24 hours, notification within 72 hours, final report 14 days after a fix has been made available or, for incidents, one month after the notification. Whether the misuse of default passwords counts as an actively exploited vulnerability in an individual case requires legal review.
Who do I have to report an attack on my refrigeration system to?+
That depends on your role. Companies in Germany that are subject to NIS2 report significant incidents via the BSI reporting portal: early warning within 24 hours, notification within 72 hours, final report one month later. Businesses that are not covered, such as individual supermarkets or butcher’s shops, are not required to report; they can inform the BSI voluntarily and should file a criminal complaint with the police Central Contact Point for Cybercrime (ZAC) in their federal state. In Switzerland, operators of critical infrastructure report to the BACS within 24 hours; all others can report voluntarily. Manufacturers report actively exploited vulnerabilities under the CRA via the ENISA Single Reporting Platform.
What role does the supply chain play?+
A decisive one. The controllers come from the manufacturer, while installation, maintenance and remote access are usually in the hands of refrigeration contractors and service providers. At the French blood donation service EFS, the attack came through a service provider’s remote monitoring. NIS2 therefore requires suppliers and service providers to be included in risk management.
How do I check whether my refrigeration systems are at risk?+
Check your router for port forwarding, NAT or UPnP rules that point to controllers, and open the site’s public IP address from outside, for example on a smartphone with Wi-Fi switched off: a controller login page must not appear there. You can also check whether the address is listed by search engines such as Shodan or Censys. Cellular modems in the control cabinet often have their own internet connection, so ask your refrigeration service provider about all remote access points. Also check passwords, firmware and end of support, and test whether temperature alarms reach on-call staff at night. VamiSec supports you with an external check and an inventory of your suppliers.
How does VamiSec support you?+
With VamiGRC, you implement NIS2 and the CRA in one system and manage your suppliers. With VamiAppSec, manufacturers embed security testing in their development and prepare CRA reports. With VamiRedteam, you keep an eye on your authorized, externally reachable attack surface around the clock. These are complemented by OT and IoT pentests, NIS2 and CRA consulting and our CSIRT for emergencies.